Quelle
Zugriffsmodell & Konnektivität — StrongDM
Geprüft für StrongDM am 24. Nov 2026
- Seite
- https://docs.strongdm.com/admin/networking/gateways-and-relays
- Geprüft
- 24 Nov 2026, 12:13 UTC
- Wie Sie es nutzen dürfen
- Öffentliche Seite, Crawling erlaubt
Technische Details
- Typ
- page
- HTTP-Status
- 200
- Inhalts-Hash
- sha256:0a8e5add2e8bdcc1ebd9e3eeaf9b4d3c5596fcf3115a83b83b6973325f2ba1b2
- Erlaubnis
- robots_ok
- Screenshot
- Screenshot liegt vor (interner Beleg, nicht veröffentlicht)
Zitiert von
Aus dieser Quelle gelesene Angaben
-
Gateways role Fehler melden
“Gateways serve as the primary entry point to a StrongDM network. Gateways have an assigned IP address and optional DNS entry.”
-
Relays role Fehler melden
“Unlike a gateway, the relay does not listen for client connections.”
-
Relay reverse tunnel Fehler melden
“Relays create a reverse tunnel to form connections to the gateway. With this action, they preserve the egress-only nature of your firewall”
-
Gateway min count Fehler melden
“You need at least one gateway to connect to resources, but we recommend running them in pairs.”
-
Gateway relay pairing Fehler melden
“We recommend deploying gateways and relays in pairs for redundancy.”
-
Gateway max recommendation Fehler melden
“Aim for 20 gateways maximum and have as many relays as necessary to enable the desired data flow or segregation.”
-
Deployment targets Fehler melden
“Gateways can be deployed as a native Linux service, Docker container, or Kubernetes container.”
-
Relay deployment targets Fehler melden
“The relay component can be deployed as a native Linux service, Docker container, or Kubernetes container.”
-
Node certificate rotation Fehler melden
“Certificates for gateways automatically regenerate 14 days before they expire. During this process, the gateway will restart, typically without a noticeable impact on services.”
-
Gateway default port Fehler melden
“The Advertised port (default 5000) is the port that the service listens on.”
-
Node host requirements Fehler melden
“Set up a 64-bit Linux instance to run the gateway. Machines should have at least 2 CPUs and 4 GB of memory.”
-
Selinux requirement Fehler melden
“If the instance is using SELinux, you need to disable SELinux to install the gateway.”
-
Node ip immutable Fehler melden
“Because a node's IP address cannot be changed in StrongDM after the node is created, recover by creating a new node and updating the token on the host”
-
Credentials handling Fehler melden
“Both gateways and relays also decrypt end-user credentials and deconstruct requests for auditing purposes.”
-
Load balancer placement Fehler melden
“Do not place gateways and relays behind a load balancer. If you must do so (such as with a cluster) there must be a 1:1 relationship between the port and the container.”
-
Autoscaling supported Fehler melden
“Deploying new gateways and relays via autoscaling is all right, but failover and routing are handled by StrongDM.”
-
Relay use cases Fehler melden
“Segmented networks for Protected Health Information (PHI), Personally Identifiable Information (PII), or other sensitive data, with separate VPCs with additional compliance requirements”
-
Egress requirements Fehler melden
“app.strongdm.com:443 (which resolves to multiple IP addresses) downloads.strongdm.com:443 (which resolves to multiple IP addresses) for downloading updates”
-
Corporate proxy support Fehler melden
“if your organization requires outbound traffic from your infrastructure to pass through your own corporate proxy, you must set either or both of the HTTP_PROXY/HTTPS_PROXY environment variables (or the StrongDM-specific version).”
-
Node auto removal Fehler melden
“Gateways and relays without a heartbeat for 30 days are automatically removed.”
-
Admin UI filters Fehler melden
“You can use search filters to search for specific gateways and relays and display them according to their name, status, listen address, or bind address.”
-
Node statuses Fehler melden
“awaiting restart”
-
Liveness check Fehler melden
“The StrongDM binary includes a configurable 'liveness' URL that you can use to verify that the relay/gateway is alive and functioning properly.”
-
Kubernetes liveness Fehler melden
“Kubernetes: Liveness check is already enabled in the Kubernetes configuration.”
-
Capacity scaling guidance Fehler melden
“If you note that more than 50% of your CPU cores are constantly saturated, then this is a good measure that it is time to scale up.”
-
Scale up options Fehler melden
“you can either add a new gateway or relay or, if you are running in a virtual environment, simply add additional CPUs to the system.”
-
Terraform setup Fehler melden
“If you are familiar with Terraform, and choose to set up a gateway in AWS, you can automate gateway setup!”
-
Install token modes Fehler melden
“The flags --gateway and --relay alias to --node as well. The token that you paste in the next step, not the install flag used here, will dictate whether the software installs in "relay mode" or as a gateway.”
-
Installer local user requirement Fehler melden
“The installer must be run by a user that exists in the /etc/passwd file. Any users remotely authenticated, such as with LDAP or an SSO service, will fail to complete the installation.”
-
Downloads regions Fehler melden
“US UK EU”
-
Token shown once Fehler melden
“Carefully copy the token, as it is shown to you only one time.”
-
Proxy clusters alternative Fehler melden
“For more flexibility in network segmentation or for larger amounts of deployed resources and proxies, consider using Proxy Clusters.”
Bewertungen, die auf diesen Datensatz verweisen
- DevOps-Engineer Zugriffsmodell & Konnektivität
- DevOps-Engineer Betriebsmodell, API & Verwaltung
- DevOps-Engineer Architektur, Zuverlässigkeit & Sicherheitsnachweise
- DevOps-Engineer Europäische Souveränität
- IT-Verantwortlicher Zugriffsmodell & Konnektivität
- IT-Verantwortlicher Betriebsmodell, API & Verwaltung
- IT-Verantwortlicher Architektur, Zuverlässigkeit & Sicherheitsnachweise
- IT-Verantwortlicher Europäische Souveränität
- MSP-Techniker Zugriffsmodell & Konnektivität
- MSP-Techniker Betriebsmodell, API & Verwaltung
- MSP-Techniker Architektur, Zuverlässigkeit & Sicherheitsnachweise
- MSP-Techniker Europäische Souveränität
- Betriebsmanager Zugriffsmodell & Konnektivität
- Betriebsmanager Betriebsmodell, API & Verwaltung
- Betriebsmanager Architektur, Zuverlässigkeit & Sicherheitsnachweise
- Betriebsmanager Europäische Souveränität
- Informationssicherheitsbeauftragter Zugriffsmodell & Konnektivität
- Informationssicherheitsbeauftragter Betriebsmodell, API & Verwaltung
- Informationssicherheitsbeauftragter Architektur, Zuverlässigkeit & Sicherheitsnachweise
- Informationssicherheitsbeauftragter Europäische Souveränität
- Skeptiker Zugriffsmodell & Konnektivität
- Skeptiker Betriebsmodell, API & Verwaltung
- Skeptiker Architektur, Zuverlässigkeit & Sicherheitsnachweise
- Skeptiker Europäische Souveränität